Fleck Control Valve

Small-sized home use, and small and middle sized: BR ,5600,5000(ProFloSE)
One piston business and industrial use: 2850, 3150
Dual piston business and industrial use: 2900, 3900
Double-tank continuous operation: 9000, 9100, 9500.

BINRUN Series Model.
It is mainly used for domestic water softener and water purifier and other water treatment equipment, functioned with automatic water softening, backwashing.
Pretreatment system can also be applied to small-scale water treatment systems and commercial reverse osmosis equipment.

BINRUN control valves

Valve material ABS+30%
Inlet/Outlet pipe diameter 3/4",1"(DN20,DN25)
Inlet/Outlet thread NPT/BSP
m³/h 0.3-3.0
m³/h back-wash flow 1.5
Regeneration Down-Flow
Suited base diameter (Soften) ∅150-∅300(6"-12")
Suited base diameter(filter) ∅150-∅250(6"-10")
POWER 220V/24V, 50/60Hz
Control method and function Time-oriented, flow-oriented (soft water valve only) Be able to randomly choose between auto-mechanical and auto-digital

5600, 5000(ProFloSE) Control Valve

Simple auto-digital and auto-mechanical design. Stable and easy to manage

Model 5600 5000(ProFloSE)
Valve material Noryl
Inlet/Outlet pipe diameter 3/4", 1"
Inlet/Outlet thread NPT/BSP
Continuous water inflow(m³/h)① 4.54 4.77
Peak water inflow (m³/h)② 5.9 6.1
Back-wash flow(m³/h)② 1.59 3.86
Regeneration Down/Up flow
Suited base diameter (Soften) ∅150-∅400(6"-16")
Suited base diameter(filter) ∅150-∅250(6"-10")
POWER 220V/24V, 50/60Hz 24V, 50/60Hz
Control method and function Timed and flowed-oriented(soft water valve only)
Be able to randomly choose between auto-mechanical and auto-digital
Time-oriented, flow-oriented(soft water valve only)auto-mechanical (SE) control

① is theoretical number under the condition of 0.35Mpa inflow pressure and 0.1Mpa pressure descent.
② is theoretical number under the condition of 0.35Mpa inflow pressure and 0.175Mpa pressure descent.


FLECK single piston, valve automation and control systems for industrial use
Used in commercial and industrial water treatment equipment, automatic softener cleaning function. reclaim equipment used in single pipe pistons, piston twin tube, multi-tube piston system. Heating boilers are used in the pretreatment system, water softeners, filters and reverse osmosis unit.

2510,2750: suitable for large residential, commercial, industrial water treatment systems, easy to install and run stably with good quality.

Model 2510 2750
Valve material Noryl Nonleaded brass
Inlet/Outlet pipe diameter 3/4", 1" (DN20,DN25) 1"M(DN25)
Inlet/Outlet thread NPT/BSP M
Continuous water inflow(m3/h)① 4.3 5.9
Peak water inflow(m3/h)② 5.4 7.5
Back-wash flow(m3/h)② 3.86 5.68
Regeneration Down Flow Down/Up flow
Suited base diameter (Soften) ∅150-∅400(6"-16") ∅250-∅600(10"-24")
Suited base diameter(filter) ∅150-∅400(8"-16") ∅200-∅400(6"-16")
POWER 220V/24V, 50/60Hz
Control method and function Timed and flowed-oriented(soft water valve only)
Be able to randomly choose between auto-mechanical and auto-digital

① Theoretical value on the condition when the inflow of gas pressure is 0.35MPa and pressure is 0.1MPa


Series 2850, Series 3150

1.5"-2" Inlet/Outlet diameter, meet relatively large inflow of commercial / industrial water treatment system, easy to operate, stable operation and easy maintenance.easy to install, operate stably and provide good quality of water.

Model 2850 3150
Valve material Nonleaded brass
Inlet/Outlet pipe diameter 1.5"F (DN40) 2"F (DN50)
Inlet/Outlet thread NPT
Continuous water inflow(m³/h)① 11.5 21.59(Top) 22.72(Side)
Peak water inflow (m³/h)② 15 28.18(Top) 29.31(Side)
Back-wash flow(m³/h)② 11.1 23.85(Top) 24.76(Side)
Regeneration Down-Flow Down/Up flow
Suited base diameter (Soften) ∅250-∅750(10"-30") ∅600-∅1600(24"-63")
Suited base diameter(filter) ∅250-∅600(10"-24") ∅600-∅1000(24"-42")
POWER 220V/24V, 50/60Hz
Control method and function Time-oriented, flow-oriented(soft water), be able to randomly choose between electronic(SE/SXT Or NT/NXT) and auto-digital.
Operate 2 valves or more than 2 valves at the same time to distinguish regeneration system (#6 system)

① is theoretical number under the condition of 0.35Mpa inflow pressure and 0.1Mpa pressure descent.
② is theoretical number under the condition of 0.35Mpa inflow pressure and 0.175Mpa pressure descent.

FLECK Dual piston Industrial system control Valve

mainly used in industrial high-volume continuous softening water treatment systems and filtration equipment.

Model 2900 3900
Valve material Nonleaded brass
Inlet/Outlet pipe diameter 2"F (DN50) 3"F (DN80)
Inlet/Outlet thread NPT
Continuous water inflow(m³/h)① 24.07 56.81
Peak water inflow (m³/h)② 31.8 73.86
Back-wash flow(m³/h)② 5.68 29.54
Regeneration Down/Up flow Down/Up flow
Suited base diameter (Soften) ∅350-∅750(14"-30") ∅600-∅1600(24"-63")
Suited base diameter(filter) ∅350-∅500(14"-21") ∅600-∅1000(24"-42")
POWER 220V/24V, 50/60Hz
Control method and function Time-oriented, flow-oriented(soft water), be able to randomly choose between electronic(SE/SXT Or NT/NXT) and auto-digital. Operate 2 valves or more than 2 valves at the same time to distinguish regeneration system (5#, #6 system)

① is theoretical number under the condition of 0.35Mpa inflow pressure and 0.1Mpa pressure descent.
② is theoretical number under the condition of 0.35Mpa inflow pressure and 0.175Mpa pressure descent.

Dual Tank Control Valve

Dual control hydraulic balance piston, to ensure consecutive water supply, stable in/outlet switch, superior performance.

Model 9100
Valve material Noryl
Inlet/Outlet pipe diameter 3/4", 1" (DN20,DN25)
Inlet/Outlet thread NPT/BSP
Continuous water inflow(m³/h)① 4.41 (3/4") 4.56 (1")
Peak water inflow (m³/h)② 5.68 (3/4") 5.9 (1")
Back-wash flow(m³/h)② 1.93
Regeneration Down/Up flow
Suited base diameter (Soften) ∅150-∅400(6"-16")
POWER 220V/24V, 50/60Hz
Control method and function Double-tank continuous operating flow-oriented, Be able to randomly choose between auto-mechanical and auto-digital.

① is theoretical number under the condition of 0.35Mpa inflow pressure and 0.1Mpa pressure descent.
② is theoretical number under the condition of 0.35Mpa inflow pressure and 0.175Mpa pressure descent.

Model 9000 9500
Valve material brass
Inlet/Outlet pipe diameter 3/4", 1"F (DN20, DN25) 1.5"F (DN40)
Inlet/Outlet thread NPT/BSP NPT
Continuous water inflow(m³/h)① 4.09 (3/4") 4.77 (1") 9.77
Peak water inflow (m³/h)② 5.45 (3/4") 6.36 (1") 12.5
Back-wash flow(m³/h) 1.93 3.63
Regeneration Down-Flow
Suited base diameter (Soften) ∅150-∅400(6"-16") ∅250-∅600(10"-24")
POWER 220V/24V, 50/60Hz
Control method and function Double-tank continuous operating flow-oriented. Be able to randomly choose between auto-mechanical(SE Or SXT) and auto-digital. Double-tank continuous operating flow-oriented. Be able to randomly choose between auto-mechanical(SXT) and auto-digital

① is theoretical number under the condition of 0.35Mpa inflow pressure and 0.1Mpa pressure descent.
② is theoretical number under the condition of 0.35Mpa inflow pressure and 0.175Mpa pressure descent.